Opens a dialog box designed to edit inductors and capacitors.
| Number | Type | Compulsory | Default | Description | 
|---|---|---|---|---|
| 1 | string array | Yes | 
 | Initial values | 
| 2 | string | Yes | 
 | Options | 
| 3 | string | No | 
 | Parameter names | 
| 4 | string | No | 
 | Parameter values | 
First element is the initial value of device. Second element is the initial condition.
Three element string array. Each field has the meaning defined in the following table:
| Index | Description | 
|---|---|
| 0 | Caption for value group box | 
| 1 | Initial range. Possible values: 'E6', 'E12', 'E24' | 
| 2 | Type of device. Possible values: 'capacitor', 'inductor'. This controls the Initial condition group box design | 
| 3 | Initial condition enabled for operating point check box. ('true' or 'false') | 
| 4 | Initial condition enabled fro transient check box. ('true' or 'false') | 
| 5 | Initial condition enabled for AC check box. ('true' or 'false') | 
| 6 | Initial condition enabled for DC check box. ('true' or 'false') | 
String array defining list of parameter names. See argument 4.
String array defining list of parameter values. If arguments 3 and 4 are supplied the Parameters... button will be visible. This button opens another dialog box that provides the facility to edit these parameters' values.
Return type: string array
The function returns a string array in the following form:
| Index | Description | 
|---|---|
| 0 | Value in Result box | 
| 1 | Value in Initial Voltage or Initial Current box. Empty if Open circuit or Short circuit is selected | 
| 2 | Number of parameter values. | 
| 3 | onwards The values of the parameters in the order they were passed. | 
| number of parameters +3 | Initial condition enabled for operating point check box ('true' or 'false') | 
| number of parameters +4 | Initial condition enabled fro transient check box ('true' or 'false') | 
| number of parameters +5 | Initial condition enabled for AC check box. ('true' or 'false') | 
| number of parameters +6 | Initial condition enabled for DC check box. ('true' or 'false') | 
| 
 | ||