Opens a dialog box intended to select values for passive components such as resistors and capacitors. The dialog below is displayed after executing the following:
| Let paramNames = ['temp','tc1','tc2'] | 
| Let paramValues = [",","] | 
| Show NewPassiveDialog('1k',['Select Value','e24'], paramNames, paramValues) | 
         
            
| Number | Type | Compulsory | Default | Description | 
|---|---|---|---|---|
| 1 | string | Yes | 
 | Initial value | 
| 2 | string array | No | ['Select value', 'E12'] | [message series] | 
| 3 | string array | No | <<empty>> | Parameter names | 
| 4 | string array | No | <<empty>> | Parameter values | 
Initial value displayed in "Result" box. "Base" and "Decade" will be adjusted accordingly.
Two element string array:
| 0 | Message displayed at the top of the box. | 
| 1 | Initial setting of preferred value series. Possible values: 'E6, 'E12', 'E24' | 
String array defining list of parameter names. See argument 4.
String array defining list of parameter values. If arguments 3 and 4 are supplied the "Parameters..." button will be visible. This button opens another dialog box that provides the facility to edit these parameters' values.
Return type: string array
The function returns a string array in the following form:
| Index | Description | 
|---|---|
| 0 | Value in "Result" box | 
| 1 | Number of parameter values | 
| 2 | The values of the parameters in the order they were passed (onwards values) | 
| 
 | ||