Opens the choose analysis dialog initialised according to the analysis controls passed as the argument. Returns a new analysis spec that may be passed to a netlist.
| Number | Type | Compulsory | Default | Description | 
|---|---|---|---|---|
| 1 | string | Yes | 
 | Analysis spec | 
Analysis spec as it would appear in a netlist or the F11 window. E.g. lines beginning with .TRAN, .AC, .DC etc.
Return type: string array
String array of length 2. Element 0 contains the new analysis spec. Note individual simulator controls are separated by new line characters.
Element 1 identifies how the user closed the dialog box as defined below:
| Run button | '2' | 
| Cancel button | '1' | 
| OK button | '0' | 
| 
 | ||