In this Topic Hide
Axxxx out model_name |
Name | Description | Flow | Type |
---|---|---|---|
out | Output | out | d |
.MODEL model_name d_pulldown parameters |
Name | Description | Type | Default | Limits |
---|---|---|---|---|
load | Load value (F) | real | 0 | none |
strong | Strong output | boolean | FALSE | none |
out_family | Output logic family | string | UNIV | none |
This is a single terminal device that can provide either a RESISTIVE or STRONG logic '0'. When resistive it can be used for wire-OR connected open emitter outputs. If STRONG is specified (by the STRONG parameter) its main application is as a digital ground connection.
|