DVM - Design Verification Module

DC Input Susceptibility Source

The DC input susceptibility source injects a small signal AC voltage into the input during an AC analysis. For the POP and transient analyses, the small signal portion of the source is disabled and the source is modeled by a constant DC voltage and a source resistance.

Unlike the DC Input Impedance Source, this source doesn't include any probes to generate the conducted susceptibility plots. Instead, the plots are created using a special conducted susceptibility probe.

Model Name

DC Input Susceptibility Source

Simulator

This device is compatible with both the SIMetrix and SIMPLIS simulators.

Parts Selector
Menu Location

DVM ▶Source ▶Input Source

Symbol Library

None - the symbol is automatically generated when placed or edited.

Model File

SIMPLIS_DVM_ADVANCED.lb

Subcircuit Name SIMPLIS_DVM_ADVANCED_SOURCE_DC_SUSCEPTIBILITY
Schematic DVM DC Source (SUSCEPTIBILITY)

DC Input Susceptibility Source Parameters

The following table explains the relevant parameters.

Parameter Name Default Data Type Range Units Parameter Description
DC_VOLTAGE 5 Real min:0 V

DC voltage of input source

SOURCE_NAME SRC String n/a n/a

Name of the DVM source. This name cannot contain spaces.

SOURCE_RESISTANCE 0.4 Real min:0

Sets the source resistance of the source.

MEASURE_SUSCEPTIBILITY

0 Real 0 or 1   A flag used by DVM to measure the Conducted Susceptibility for this input source. This flag also enables the small signal AC source. When both MEASURE_SUSCEPTIBILITY and MULTI_TONE are equal to 1, the source is set to measure a Multi-Tone Input Impedance.

MULTI_TONE

0 Real 0 or 1   Enables Multi-Tone AC analysis for this source. For small signal POP and AC analyses, this is set to 0.

DC Input Susceptibility Source - Multi-Tone AC Analysis

The following table summarizes the parameters used when a Multi-Tone AC Analysis is specified. The source uses these parameters only if the MULTI_TONE property is set to 1.

Parameter Name Default Data Type Range Units Parameter Description

INJ_AMP

10m Real   V The RMS injection amplitude for the Multi-Tone AC source included in this source.

MEASURE_SUSCEPTIBILITY

0 Real 0 or 1   A flag used by DVM to measure the Conducted Susceptibility for this input source. This flag also enables the small signal AC source. When both MEASURE_SUSCEPTIBILITY and MULTI_TONE are equal to 1, the source is set to measure a Multi-Tone Input Impedance.

MULTI_TONE

0 Real 0 or 1   Enables Multi-Tone AC analysis for this source. For small signal POP and AC analyses, this is set to 0.

N_PT

10 Real     The number of points per decade when the SWEEP_TYPE is 1 or 2. Unused when the SWEEP_TYPE is 0 or 1.

START_FREQ

1k Real   Hz The starting frequency for the Multi-Tone AC Analysis

STOP_FREQ

100k Real   Hz The ending frequency for the Multi-Tone AC Analysis

SWEEP_TYPE

1 Real 0, 1, 2 or 3
 
  One of the following:
  • 0 = Single Frequency passed as START_FREQ
  • 1 = Linear Sweep
  • 2 = Decade Sweep
  • 3 = Decade sweep with linear first decade

TIME_DELAY

10u Real   s The time delay for the AC Multi-Tone injection. This time delay is converted into a phase delay and is used to ensure that the Multi-Tone AC injection starts at the same phase angle where the FindAcSteadyState() test ended.