» DVM Test Report: Transient|FindACSteadyState|HL_Maximum|F_Low|Enabled|100% Load

Test Details
Schematic DVM_PFC_Continuous_Conduction_Mode.sxsch
Test Transient|FindACSteadyState|HL_Maximum|F_Low|Enabled|100% Load
Date / Time 2/7/2015 10:47:57 AM
Report Directory ac_dc_built_in\Transient\FindACSteadyState\HL_Maximum\F_Low\Enabled\100%Load
Log File report.txt
Screenshot schematic.png
Status PASS
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
Frequency(Line) 50
VPFCOutput %_diff_last_2_linecycles 0.0000000792304%
ILine
MIN
-1.1732
MAX
1.1732
IPFCOutput
MIN
494.094m
MAX
506.096m
VLine
MIN
-374.368
MAX
374.368
RMS
265
VPFCOutput
MIN
395.275
MAX
404.877
VPFCOutput At Simulation Start Time
AVG
400.097
VPFCOutput Last LineCycle
AVG
400.097
VPFCOutput Previous LineCycle
AVG
400.097
Measured Spec Values
AC_Settling(PFCOutput) PASS: Voltage across PFCOutput has settled to (792.304p) % and is less than or equal to Max Settling Spec of (10m) %
Max_VPFCOutput PASS: Max. Output1 Voltage (404.877) is less than or equal to Max. Output1 Voltage Spec (420)
PFCOutput
VPFCOutput
IPFCOutput
SXGPH File simplis_tran2_34.sxgph
Line
VLine
ILine
SXGPH File simplis_tran2_39.sxgph
Other SXGPH Files
AC#tran simplis_tran2_28.sxgph