» DVM Test Report: Transient|LineSag|LL_Nominal_to_LL_Sag|F_High|100% Load

Test Details
Schematic DVM_PFC_Continuous_Conduction_Mode.sxsch
Test Transient|LineSag|LL_Nominal_to_LL_Sag|F_High|100% Load
Date / Time 2/7/2015 11:00:24 AM
Report Directory ac_dc_built_in\Transient\LineSag\LL_Nominal_to_LL_Sag\F_High\100%Load
Log File report.txt
Screenshot schematic.png
Status FAIL
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
Frequency(Line) 60
VPFCOutput %_diff_last_2_linecycles 0.109109%
vout1_recovery_time 40.8554m
ILine
MIN
-4.1693
MAX
5.02082
RMS
1.82367
ILine During Sag
MAX
3.93964
RMS
2.53544
ILine Inrush Current
MAX
5.02082
IPFCOutput
MIN
469.464m
MAX
540.345m
VLine
MIN
-161.782
MAX
161.801
VLine After Sag
RMS
115
VLine During Sag
RMS
85
VPFCOutput
MIN
375.571
MAX
432.276
VPFCOutput At Simulation Start Time
AVG
400.058
VPFCOutput During Sag
MIN
375.571
VPFCOutput Last LineCycle
AVG
401.038
VPFCOutput Previous LineCycle
AVG
401.475
VPFCOutput overshoot
MAX
432.276
Measured Spec Values
AC_Settling(PFCOutput) PASS: Voltage across PFCOutput has settled to (1.09109m) % and is less than or equal to Max Settling Spec of (10m) %
Max_ILine_Inrush PASS: Max. Inrush Current after Line Sag for Line (5.02082) is less than or equal to Max. Inrush Spec of (15)
Max_VPFCOutput FAIL: Max. Output1 Voltage (432.276) is not less than or equal to Max. Output1 Voltage Spec (420)
Max_VPFCOutput_overshoot FAIL: Max. Overshoot Output1 Voltage (432.276) is not less than or equal to Max. Overshoot Output1 Voltage Spec (420)
Min_VPFCOutput FAIL: Min. Output1 Voltage (375.571) is not greater than or equal to Min. Output1 Voltage Spec (380)
PFCOutput
VPFCOutput
IPFCOutput
SXGPH File simplis_tran13_417.sxgph
Line
VLine
ILine
SXGPH File simplis_tran13_422.sxgph
Other SXGPH Files
AC#tran simplis_tran13_411.sxgph