Test Details | |
Schematic | DVM_PFC_Continuous_Conduction_Mode.sxsch |
Test | Transient|LineSag|LL_Nominal_to_LL_Sag|F_High|100% Load |
Date / Time | 2/7/2015 11:00:24 AM |
Report Directory | ac_dc_built_in\Transient\LineSag\LL_Nominal_to_LL_Sag\F_High\100%Load |
Log File | report.txt |
Screenshot | schematic.png |
Status | FAIL |
Simulator | simplis |
Deck | input.deck |
Init | input.deck.init |
Measured Scalar Values | |
Frequency(Line) | 60 |
VPFCOutput %_diff_last_2_linecycles | 0.109109% |
vout1_recovery_time | 40.8554m |
ILine | MIN -4.1693 MAX 5.02082 RMS 1.82367 |
ILine During Sag | MAX 3.93964 RMS 2.53544 |
ILine Inrush Current | MAX 5.02082 |
IPFCOutput | MIN 469.464m MAX 540.345m |
VLine | MIN -161.782 MAX 161.801 |
VLine After Sag | RMS 115 |
VLine During Sag | RMS 85 |
VPFCOutput | MIN 375.571 MAX 432.276 |
VPFCOutput At Simulation Start Time | AVG 400.058 |
VPFCOutput During Sag | MIN 375.571 |
VPFCOutput Last LineCycle | AVG 401.038 |
VPFCOutput Previous LineCycle | AVG 401.475 |
VPFCOutput overshoot | MAX 432.276 |
Measured Spec Values | |
AC_Settling(PFCOutput) | PASS: Voltage across PFCOutput has settled to (1.09109m) % and is less than or equal to Max Settling Spec of (10m) % |
Max_ILine_Inrush | PASS: Max. Inrush Current after Line Sag for Line (5.02082) is less than or equal to Max. Inrush Spec of (15) |
Max_VPFCOutput | FAIL: Max. Output1 Voltage (432.276) is not less than or equal to Max. Output1 Voltage Spec (420) |
Max_VPFCOutput_overshoot | FAIL: Max. Overshoot Output1 Voltage (432.276) is not less than or equal to Max. Overshoot Output1 Voltage Spec (420) |
Min_VPFCOutput | FAIL: Min. Output1 Voltage (375.571) is not greater than or equal to Min. Output1 Voltage Spec (380) |
PFCOutput
VPFCOutput
IPFCOutput
|
|
SXGPH File | simplis_tran13_417.sxgph |
Line
VLine
ILine
|
|
SXGPH File | simplis_tran13_422.sxgph |
Other SXGPH Files | |
AC#tran | simplis_tran13_411.sxgph |