Test Details | |
Schematic | DVM_PFC_Continuous_Conduction_Mode.sxsch |
Test | Transient|LineStartup|LL_Maximum|F_High|Light Load |
Date / Time | 2/7/2015 10:54:32 AM |
Report Directory | ac_dc_built_in\Transient\LineStartup\LL_Maximum\F_High\LightLoad |
Log File | report.txt |
Screenshot | schematic.png |
Status | FAIL |
Simulator | simplis |
Deck | input.deck |
Init | input.deck.init |
Measured Scalar Values | |
Frequency(Line) | 60 |
VPFCOutput %_diff_last_2_linecycles | 0.00767285% |
vout1_turn_on_time | 409.172m |
ILine | MIN -5.36204 MAX 17.3154 RMS 314.312m |
ILine Inrush Current | MAX 17.3154 |
IPFCOutput | MIN -60.3978E-27 MAX 101.67m |
IPFCOutput in Reg. | AVG 100.043m MIN 99.8474m MAX 100.239m RMS 100.043m |
VLine | MIN -187.27 MAX 190.201 RMS 132 |
VPFCOutput | MIN -241.591E-24 MAX 406.68 |
VPFCOutput At Simulation Start Time | AVG -121.187E-24 |
VPFCOutput Last LineCycle | AVG 400.157 |
VPFCOutput Previous LineCycle | AVG 400.188 |
VPFCOutput in Reg. | AVG 400.173 MIN 399.39 MAX 400.955 RMS 400.173 |
Measured Spec Values | |
AC_Settling(PFCOutput) | PASS: Voltage across PFCOutput has settled to (76.7285u) % and is less than or equal to Max Settling Spec of (10m) % |
Max_ILine_Inrush | FAIL: Max. Inrush Current for Line (17.3154) is greater than or equal to Max. Inrush Spec of (15) |
Max_VPFCOutput | PASS: Max. Output1 Voltage (406.68) is less than or equal to Max. Output1 Voltage Spec (420) |
Max_VPFCOutput_overshoot | PASS: Max. Overshoot Output1 Voltage (406.68) is less than or equal to Max. Overshoot Output1 Voltage Spec (420) |
Max_VPFCOutput_reg | PASS: Max. Output1 Voltage in Reg. (400.955) is less than or equal to Max. Output1 Voltage Spec (420) |
Min_VPFCOutput_reg | PASS: Min. Output1 Voltage in Reg. (399.39) is greater than or equal to Min. Output1 Voltage Spec (380) |
PFCOutput
VPFCOutput
IPFCOutput
|
|
SXGPH File | simplis_tran8_272.sxgph |
Line
VLine
ILine
|
|
SXGPH File | simplis_tran8_277.sxgph |
Other SXGPH Files | |
AC#tran | simplis_tran8_266.sxgph |