back to overview ▲

» DVM Test Report: Transient|Step Load|Vin Nominal|50% Load to 100% Load

Test Details
Schematic LTC3406B- DVM ADVANCED.sxsch
Test Transient|Step Load|Vin Nominal|50% Load to 100% Load
Date / Time 2/7/2015 10:18:18 AM
Report Directory dc_dc_built_in\Transient\StepLoad\Vin Nominal\50% Load to 100% Load
Log File report.txt
Screenshot schematic.png
Status FAIL
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
sw_freq 955.626k
vout1_recovery_time 22.7793u
FREQUENCY
MIN
0
MAX
5
ILOAD1
MIN
748.345m
MAX
1.52984
ISRC1
MIN
423.431u
MAX
1.92041
VLOAD1
MIN
1.18142
MAX
1.56487
VSRC1
MIN
4.99808
MAX
5
Measured Spec Values
Max_VLOAD1 PASS: Max. Output1 Voltage (1.56487) is less than or equal to Max. Output1 Voltage Spec (1.58025)
Max_VLOAD1_overshoot PASS: Max. Overshoot Output1 Voltage (1.56487) is less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025)
Min_VLOAD1 FAIL: Min. Output1 Voltage (1.18142) is not greater than or equal to Min. Output1 Voltage Spec (1.42975)
LOAD1
VLOAD1
ILOAD1
SXGPH File simplis_tran1_584.sxgph
SRC1
VSRC1
ISRC1
SXGPH File simplis_tran1_579.sxgph
default
FREQUENCY
SXGPH File simplis_tran1_562.sxgph
Other SXGPH Files
clock#tran simplis_tran1_567.sxgph