Test Details | |
Schematic | LTC3406B- DVM ADVANCED.sxsch |
Test | Transient|Step Load|Vin Nominal|50% Load to 100% Load |
Date / Time | 2/7/2015 10:18:18 AM |
Report Directory | dc_dc_built_in\Transient\StepLoad\Vin Nominal\50% Load to 100% Load |
Log File | report.txt |
Screenshot | schematic.png |
Status | FAIL |
Simulator | simplis |
Deck | input.deck |
Init | input.deck.init |
Measured Scalar Values | |
sw_freq | 955.626k |
vout1_recovery_time | 22.7793u |
FREQUENCY | MIN 0 MAX 5 |
ILOAD1 | MIN 748.345m MAX 1.52984 |
ISRC1 | MIN 423.431u MAX 1.92041 |
VLOAD1 | MIN 1.18142 MAX 1.56487 |
VSRC1 | MIN 4.99808 MAX 5 |
Measured Spec Values | |
Max_VLOAD1 | PASS: Max. Output1 Voltage (1.56487) is less than or equal to Max. Output1 Voltage Spec (1.58025) |
Max_VLOAD1_overshoot | PASS: Max. Overshoot Output1 Voltage (1.56487) is less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025) |
Min_VLOAD1 | FAIL: Min. Output1 Voltage (1.18142) is not greater than or equal to Min. Output1 Voltage Spec (1.42975) |
LOAD1
VLOAD1
ILOAD1
|
|
SXGPH File | simplis_tran1_584.sxgph |
SRC1
VSRC1
ISRC1
|
|
SXGPH File | simplis_tran1_579.sxgph |
default
FREQUENCY
|
|
SXGPH File | simplis_tran1_562.sxgph |
Other SXGPH Files | |
clock#tran | simplis_tran1_567.sxgph |