DefineSaturableTxDialog

Opens a dialog box to define a saturable transformer.

Arguments

Number Type Compulsory Default Description

1

string array

Yes

Core material info

2

string array

Yes

Part number info

3

real array

Yes

Winding ratios

4

real array

Yes

Initial values

Argument 1

Array of core material specifications. Each element is a string has the format:

name;model_name;saturation_flux_density

Argument 2

Array of core part specifications. Each element is a string which has the format:

name;Ae;Le;Ue;material_name

Argument 3

Array of turns ratios.

Argument 4

Real array with up to 9 elements that defines the initial values for the controls in the dialog box, as defined in the following table:

Index Description
0 Primary number of turns
1 Selected material index (into arg 1)
2 Selected part index (into arg 2). -1 for manual entry.
3 Number of primaries
4 Number of secondaries
5 Effective area
6 Effective length
7 Ue
8 Coupling factor

Returns

Return type: real array