baseschematic: ..\..\..\..\..\8.2_LLC Closed Loop.sxsch log_file: ..\..\..\dvm_advanced.log simulator: simplis screenshot: schematic.png deck: input.deck init: input.deck.init test_argument: Efficiency and Loop Characterization|Vin Minimum|25% Load datetimestamp: 12/10/2015 6:14 PM status: RUN scalar: Power(SRC)=31.6021 scalar: Power(LOAD)=30.2532 scalar: Efficiency=95.7316% feature: DVM Bode Plot#log#ac,100 spec: Min_VLOAD=pass,Min. Output1 Voltage (24.0843) is greater than or equal to Min. Output1 Voltage Spec (22.8) spec: Max_VLOAD=pass,Max. Output1 Voltage (24.109) is less than or equal to Max. Output1 Voltage Spec (25.2) stats: N/A numgraphs: 7 graphid: 1921 graphname: Primary#pop sg: simplis_pop33_1921 path: simplis_pop33_1921.sxgph curve1929:VSW,0000FF curve1950:Ir,808000 curve1952:Ip,008080 curve1953:Im,800080 curve1956:IDQ2,800000 curve1958:IDQ1,000080 png: simplis_pop33_1921.png scalar: Max(VSRC)=360.058 scalar: Avg(VSRC)=359.991 scalar: Min(VSRC)=359.94 scalar: Pk2Pk(VSRC)=117.924m scalar: RMS(VSRC)=359.991 scalar: RMS(ISRC)=307.797m scalar: Pk2Pk(ISRC)=1.17924 scalar: Min(ISRC)=-579.526m scalar: Avg(ISRC)=87.8099m scalar: Max(ISRC)=599.715m graphid: 1930 graphname: DVM SRC#pop sg: simplis_pop33_1930 path: simplis_pop33_1930.sxgph curve1934:VSRC,FF0000 curve1945:ISRC,008000 png: simplis_pop33_1930.png scalar: Frequency(CLK)=80.0052k graphid: 1935 graphname: Secondary#pop sg: simplis_pop33_1935 path: simplis_pop33_1935.sxgph curve1939:Vs,FF0000 curve1947:Is2,008000 curve1949:Is1,0000FF curve1959:ICout,808000 curve1961:CLK,008080 png: simplis_pop33_1935.png scalar: RMS(VLOAD)=24.0968 scalar: Pk2Pk(VLOAD)=24.7032m scalar: Min(VLOAD)=24.0843 scalar: Avg(VLOAD)=24.0968 scalar: Max(VLOAD)=24.109 scalar: RMS(ILOAD)=1.25549 scalar: Pk2Pk(ILOAD)=1.30442m scalar: Min(ILOAD)=1.25483 scalar: Avg(ILOAD)=1.25549 scalar: Max(ILOAD)=1.25613 graphid: 1940 graphname: DVM LOAD#pop sg: simplis_pop33_1940 path: simplis_pop33_1940.sxgph curve1944:VLOAD,FF0000 curve1954:ILOAD,008000 png: simplis_pop33_1940.png graphid: 1963 graphname: default#1963#pop sg: simplis_pop33_1963 path: simplis_pop33_1963.sxgph graphid: 1968 graphname: Modulator#pop sg: simplis_pop33_1968 path: simplis_pop33_1968.sxgph scalar: min_phase=44.7731 scalar: min_phase_freq=4.84903k scalar: phase_crossover_freq=31.4433k scalar: phase_margin=44.5241 scalar: gain_crossover_freq=4.84903k scalar: gain_margin=26.1537 graphid: 1974 graphname: DVM Bode Plot#log#ac sg: simplis_ac33_1974 path: simplis_ac33_1974.sxgph curve1978:PHASE,FF0000 curve1979:GAIN,008000 png: simplis_ac33_1974.png scalar: eta_min=95.7316% scalar: iload_min=1.25549 scalar: gxover_min=4.84903k scalar: gmargin_min=26.1537 scalar: pmargin_min=44.5241 scalar: sw_freq_min=80.0052k spec: min_gain_margin=pass,Gain Margin (26.1537) is greater than Min. Gain Margin (12) spec: min_phase_margin=pass,Phase Margin (44.5241) is greater than Min. Phase Margin (35) rstatus: PASS