baseschematic: ..\..\..\..\..\..\..\DVM_PFC_Continuous_Conduction_Mode.sxsch log_file: ..\..\..\..\..\dvm_advanced.log simulator: simplis screenshot: schematic.png deck: input.deck init: input.deck.init test_argument: Transient|LineSurge|HL_Maximum_to_HL_Surge|F_High|Light Load datetimestamp: 12/10/2015 6:33 PM status: RUN feature: DVM PFCOutput#tran scalar: Avg(VPFCOutput_in_reg)=399.977 scalar: Min(VPFCOutput_in_reg)=398.796 scalar: Pk2Pk(VPFCOutput_in_reg)=2.01824 spec: Min_VPFCOutput_in_reg=pass,Min. Output1 Voltage in Reg. (398.796) is greater than or equal to Min. Output1 Voltage Spec (380) scalar: Max(VPFCOutput_in_reg)=400.814 spec: Max_VPFCOutput_in_reg=pass,Max. Output1 Voltage in Reg. (400.814) is less than or equal to Max. Output1 Voltage Spec (420) spec: Pk2Pk_VPFCOutput_in_reg=pass,Pk-to-Pk Output1 Voltage in Reg. (2.01824) is less than or equal to Max. Output1 Voltage Spec (10) scalar: RMS(VPFCOutput_in_reg)=399.977 scalar: Overshoot_VPFCOutput=405.182 spec: Overshoot_VPFCOutput=pass,Max. Output1 Voltage (405.182) is less than or equal to Max. Output1 Voltage Spec (420) scalar: vout1_recovery_time_2=never left regulation scalar: Frequency(Line)=60 scalar: Max(ILine During Surge)=862.048m scalar: Max(ILine After Surge)=400.696m scalar: RMS(ILine During Surge)=265.716m scalar: RMS(ILine)=181.394m scalar: RMS(VLine After Surge)=265 scalar: RMS(VLine During Surge)=293 feature: DVM Line,1 scalar: Max(VPFCOutput During Surge)=405.182 scalar: Min(VPFCOutput After Surge)=397.07 scalar: Max(VPFCOutput overshoot)=402.382 feature: DVM PFCOutput,-1 scalar: VPFCOutput %_diff_last_2_linecycles=0.00345922% spec: AC_Settling(PFCOutput)=pass, Voltage across PFCOutput has settled to (34.5922u) % and is less than or equal to Max Settling Spec of (10m) % scalar: Avg(VPFCOutput Last LineCycle)=400.062 scalar: Avg(VPFCOutput Previous LineCycle)=400.048 scalar: VPFCOutput %_diff_last_2_linecycles=0.00345922% scalar: Avg(VPFCOutput At Simulation Start Time)=400.096 stats: N/A numgraphs: 3 graphid: 313 graphname: AC#tran sg: simplis_tran14_313 path: simplis_tran14_313.sxgph scalar: Max(VPFCOutput)=405.182 scalar: Min(VPFCOutput)=397.07 scalar: Min(IPFCOutput)=99.2674m scalar: Max(IPFCOutput)=101.296m graphid: 319 graphname: DVM PFCOutput#tran sg: simplis_tran14_319 path: simplis_tran14_319.sxgph curve323:VPFCOutput,FF0000 curve329:IPFCOutput,008000 png: simplis_tran14_319.png scalar: Max(VLine)=413.999 scalar: Min(VLine)=-413.988 scalar: Max(ILine)=862.048m scalar: Min(ILine)=-755.816m graphid: 324 graphname: DVM Line#tran sg: simplis_tran14_324 path: simplis_tran14_324.sxgph curve328:VLine,FF0000 curve331:ILine,008000 png: simplis_tran14_324.png rstatus: PASS