Test Details | |
Schematic | DVM_PFC_Continuous_Conduction_Mode.sxsch |
Test | Transient|FindACSteadyState|HL_Maximum|F_Low|Enabled|100% Load |
Date / Time | 12/10/2015 6:21 PM |
Report Directory | ac_dc_built_in\Transient\FindACSteadyState\HL_Maximum\F_Low\Enabled\100%Load |
Log File | report.txt |
Screenshot | schematic.png |
Status | PASS |
Simulator | simplis |
Deck | input.deck |
Init | input.deck.init |
Measured Scalar Values | |
Frequency(Line) | 50 |
ILine | MIN -1.1732 MAX 1.1732 |
IPFCOutput | MIN 494.094m MAX 506.096m |
VLine | MIN -374.368 MAX 374.368 RMS 265 |
VPFCOutput | MIN 395.275 MAX 404.877 |
VPFCOutput %_diff_last_2_linecycles | 0.0000000792304% |
VPFCOutput At Simulation Start Time | AVG 400.097 |
VPFCOutput Last LineCycle | AVG 400.097 |
VPFCOutput Previous LineCycle | AVG 400.097 |
Measured Spec Values | |
AC_Settling(PFCOutput) | PASS: Voltage across PFCOutput has settled to (792.304p) % and is less than or equal to Max Settling Spec of (10m) % |
Max_VPFCOutput | PASS: Max. Output1 Voltage (404.877) is less than or equal to Max. Output1 Voltage Spec (420) |
PFCOutput
VPFCOutput
IPFCOutput
|
|
SXGPH File | simplis_tran2_27.sxgph |
Line
VLine
ILine
|
|
SXGPH File | simplis_tran2_32.sxgph |
Other SXGPH Files | |
AC#tran | simplis_tran2_21.sxgph |