Test Details | |
Schematic | DVM_PFC_Continuous_Conduction_Mode.sxsch |
Test | Transient|LineStartup|HL_Maximum|F_Low|100% Load |
Date / Time | 12/10/2015 6:28 PM |
Report Directory | ac_dc_built_in\Transient\LineStartup\HL_Maximum\F_Low\100%Load |
Log File | report.txt |
Screenshot | schematic.png |
Status | FAIL |
Simulator | simplis |
Deck | input.deck |
Init | input.deck.init |
Measured Scalar Values | |
Frequency(Line) | 50 |
ILine | MIN -2.45893 MAX 35.8483 RMS 775.184m |
ILine Inrush Current | MAX 35.8483 |
IPFCOutput | MIN -337.338E-27 MAX 629.977m |
Overshoot_VPFCOutput | 503.982 |
VLine | MIN -375.378 MAX 374.999 RMS 265 |
vout1_turn_on_time | 307.613m |
VPFCOutput | MIN -269.87E-24 MAX 503.982 |
VPFCOutput %_diff_last_2_linecycles | 0.000123818% |
VPFCOutput At Simulation Start Time | AVG -138.672E-24 |
VPFCOutput Last LineCycle | AVG 400.098 |
VPFCOutput Previous LineCycle | AVG 400.099 |
VPFCOutput_in_reg | AVG 400.1 MIN 395.276 MAX 404.882 RMS 400.114 PK2PK 9.60525 |
Measured Spec Values | |
AC_Settling(PFCOutput) | PASS: Voltage across PFCOutput has settled to (1.23818u) % and is less than or equal to Max Settling Spec of (10m) % |
Max_ILine_Inrush | FAIL: Max. Inrush Current for Line (35.8483) is greater than or equal to Max. Inrush Spec of (15) |
Max_VPFCOutput_in_reg | PASS: Max. Output1 Voltage in Reg. (404.882) is less than or equal to Max. Output1 Voltage Spec (420) |
Min_VPFCOutput_in_reg | PASS: Min. Output1 Voltage in Reg. (395.276) is greater than or equal to Min. Output1 Voltage Spec (380) |
Overshoot_VPFCOutput | FAIL: Max. Output1 Voltage (503.982) is not less than or equal to Max. Output1 Voltage Spec (420) |
Pk2Pk_VPFCOutput_in_reg | PASS: Pk-to-Pk Output1 Voltage in Reg. (9.60525) is less than or equal to Max. Output1 Voltage Spec (10) |
PFCOutput
VPFCOutput
IPFCOutput
|
|
SXGPH File | simplis_tran9_214.sxgph |
Line
VLine
ILine
|
|
SXGPH File | simplis_tran9_219.sxgph |
Other SXGPH Files | |
AC#tran | simplis_tran9_208.sxgph |