Opens a dialog box to define an ideal transformer.
| Number | Type | Compulsory | Default | Description |
|---|---|---|---|---|
|
1 |
real array |
Yes |
|
initial inductance, coupling factors, number of windings |
|
2 |
real array |
Yes |
|
initial primary turns ratios |
|
3 |
real array |
Yes |
|
initial secondary turns ratios |
|
4 |
string |
No |
|
options |
Real array of size 6. Function of each element is described below:
| 0 | Primary 1 inductance |
| 1 | Coupling factor primary to primary |
| 2 | Coupling factor secondary to secondary |
| 3 | Coupling factor primary to secondary |
| 4 | Number of primaries |
| 5 | Number of secondaries |
Real array of primary turns ratios relative to primary 1. (The first value is the ratio of primary 1 to itself. This is of course always 1 but the value is in fact ignored).
Real array of secondary turns ratios relative to primary 1.
If set to 'nonind', the box design will that used for non-inductive transformers. These do not show inductance related parameters.
Return type: real array