In this Topic Hide
There are a number of options affecting all aspects of SIMetrix. Many of these may be viewed and adjusted using the Options dialog box, others can only be accessed from the command line using the Set and Unset commands.
This is invoked with the menu
. This brings up the following:
Undo Level | Number of levels of schematic undo. See Creating a Schematic. |
Most Recent Files | Controls how many recently used files are displayed in the File | Reopen menu |
Bias Annotation Precision | Controls the precision of the schematic voltage and current bias annotation markers. |
Auto-save interval (minutes) | Enter a value to enable schematic auto-save. SIMetrix will automatically save a backup copy of your schematic at the interval specified. If SIMetrix aborts abnormally, perhaps due to a power failure, you will be prompted to recover the auto-saved schematic when you next start SIMetrix. |
Hierarchy Highlighting | Check the Disabled box to disable highlighting through the hierarchy. With deep and complex hierarchies, net highlighting can be time-consuming. Checking this box will restrict highlighting to the current schematic only. |
Double click mode | Selects action when double clicking a schematic instance. Select Classic to retain pre version 5.0 behaviour whereby double clicking always starts a new wire. Select Edit selected part for the default behaviour which is to invoke the device value editor. |
Property Editing |
Enable GUI Property Edits: If checked, allows property text (i.e. labels) to be moved using mouse actions. Labels themselves can be editted by double clicking. See Notes on Property Text Position before checking this option. |
Placement | When to auto-repeat placement of schematic parts. If autorepeat is enabled, a new symbol to be placed is automatically displayed after each placement. This speeds the placement of many instances of the same device. |
Wiring |
Enable smart wiring enables the smart wiring algorithm. See Wiring for details about smart wiring.
Allow route through connected is an option for the smart wiring algorithm that allows it select routes that pass through existing wires that are already connected to the source or target destinations. |
Grid | Option to hide the schematic's grid. |
Initial Simulator | This is only relevant for SIMetrix/SIMPLIS products. Sets the initial simulation mode when opening a new schematic. If most or all of your work is with SIMPLIS, check SIMPLIS. This will save time switching to SIMPLIS mode for all new schematics. |
Axis line width | Width in mm of printed axis. | ||||||
Grid line width | Width in mm of printed grid lines. | ||||||
Minor grid | Width in mm of printed minor grid lines. | ||||||
Curve line width | Width in mm of printed curves. | ||||||
Curve identification |
When printing on monochrome printers or if Use markers for colour is selected, curves are differentiated using different line styles (solid, dashed etc.) and marker shapes (circles, squares etc.). For a large number of curves both methods are used but for just a few you can use this option to state your preference.
|
Probe update times |
Plots created from fixed probes are updated on a regular basis. This controls how frequently and when it starts.
Period: Update period in seconds. Start: Start delay in seconds. |
||||||||
Fixed probe global options | Default persistence: Sets the default persistence for fixed probes. This is number of curves from previous simulations that remain after a simulation. If set to 1, previous results are deleted. If set to zero all results are retained. Persistence can also be set individually for each probe. See Probe Options Sheet for details. | ||||||||
Sizes |
|
||||||||
Temporary data file delete |
Simulation data is stored in data files that are placed in the temporary data directory (see file locations below). These options control when these data files are deleted.
|
||||||||
Histogram style |
Controls the curve style used for histogram displays:
|
||||||||
Cursor readout |
Controls where cursor values are displayed.
|
Simulation data is stored in temporary data files as explained above. The data is not read into system memory until it is needed - say - to plot a graph. However, the location in the file of the various vectors is always in memory so that the data can be extracted from the file as rapidly as possible. It is this latter location data that is destroyed when a simulation run gets out of date. The file containing the data gets deleted at a time set by the above options, not necessarily when the data is no longer needed. As long as the file exists, the data can be recovered by calling
or which re builds the location data.
Library Diagnostics | Determines whether messages are displayed when models are found in the library. | ||||||
Action on unknown model parameter |
Specifies action to be taken when an unknown model parameter
is encountered. There are three options:
|
||||||
Script Options |
|
||||||
Locations in your files system of various files and folders needed for correct operation of SIMetrix.
Built-in Scripts | This is the first location that SIMetrix searches for scripts. Much of the user interface is implemented with scripts and these are all internal to the program. These can be overridden by placing scripts of the same name at this location. This allows modification of the UI. Changing this setting has no effect until you restart SIMetrix. |
Scripts | Location of script directory. This directory is searched for any scripts you run. Only change this setting if you are actually moving the script directory. Changing this setting has no effect until you restart SIMetrix. |
Start up | Current working directory on start up. |
Start up Script | Name of script that is automatically run on startup. You can place custom menu or key definitions in this file. |
System Symbols Location | Directory location where the standard symbols are located. |
Temp Data | Location of temporary simulation data files. Changing this setting has no effect until you restart SIMetrix. Note that this should always be a local directory. That is, it must not be on a remote network partition. |
User Symbols Location | Directory where user symbol libraries are expected to be located. Note, you can place symbol libraries anywhere. This directory is simply a location that some UI functions use as a default. |
Defines extensions used for the various files used by SIMetrix. These setting control what file extensions are listed for editors of the various file types and, where relevant, what action will be taken if a file of that type is dragged and dropped into the SIMetrix environment.
Many SIMetrix file types use five letter extensions beginning with .sx. This is to help prevent clashes with other applications.
For each setting, the supported extensions are separated by a semi-colon. The first in the list is the default. So, for example, the default schematic extension is sxsch so when you save a schematic without giving an extension, it will automatically be given the extension sxsch.
Schematic Files | Extensions used for schematic files. |
Data Files | Extensions used for simulation data files. |
Text files | Supported extensions for text files. |
Symbol Files | Extension used for binary schematic symbol files. This is used by the drag and drop system to detect Symbol Library files being dropped into the command shell. |
Logic Def. Files | Files used for logic definitions for the digital simulator's arbitrary logic block. If the extension is omitted in the model (FILE parameter) this will be used. |
Scripts | Default extension for scripts if called without an extension. |
Device models | SPICE model files. Used by drag and drop system to detect model file types. Note the drag and drop system will detect model files with extensions not in this list and it is not usually necessary to specify model file types here. |
Netlist Files | Files used for simulation netlists. |
Schematic Components | Extensions used by schematic component files. |
Verilog-A Files | Verilog-A Source files. |
Verilog-HDL Files | Verilog-HDL Source files. |
Defines colour syntax highlighting for the various text editors.
Defines colours for various UI elements. Note that schematic elements are defined using schematic styles.
Elements are divided into these groups:
Command Shell | Command shell text and background colours. Command shell input is the command line at the top, while command shell output is the message window below it |
File View | Colour elements of the file viewer |
Part Selector | Colour elements of the part selector |
Graph | Colour elements for graphs. This includes both text and graphic objects. Note that all text items are based on the Graph Text Colour object. Changing this object will also change the colour of the objects: Caption Colour, Free Text Colour, Text Box Text Colour, Legend Box Text Colour, Curve Marker Text Colour and Cursor Dimension Text |
Curves | Curve colours are chosen using a sequence number. The first curve on a sheet uses sequence 1, the second sequence 2 etc. New curves use the first unused sequence number. The colours associated with each sequence number can be defined here. |
All options have a name and many also have a value. These are set using the Set command and can be cleared with Unset. When an option is cleared it is restored to its default value. A complete listing of available options with possible values is given below. Note that option settings are persistent. This means that their values are stored either in the .INI file or in the system registry (see Configuration Settings) and automatically restored at the start of each subsequent SIMetrix session.
Upper and lower case letters have been used for the option names in the following listing only for clarity. Option names and their values are not in fact case sensitive. Many of the options described below are supported by the Options dialog box in which case they are noted accordingly.
Some options in the following list are marked as 'unsupported'. This means that they may be withdrawn in the future or their functionality changed.
See also
Name | Type | Description |
User interface support |
||||||
---|---|---|---|---|---|---|---|---|---|
700Extensions | Boolean | Schematic symbols for the 700 series semi-custom arrays are enabled if this is set. | |||||||
ActionOnMissingModel | string |
Default=AutoAssociate
Action to be performed when attempting to place a model from the library, but that model has not been associated. If set to AutoAssociate, will attempt to auto-associate by simulating the model |
|||||||
AlwaysUseMarkers | Boolean | Graphs are printed with markers even for colour printers. |
Options dialog |
||||||
AnnoMinSuffix | Numeric |
Default = 1
Minimum suffix used for automatic generation of schematic part references |
|||||||
AutoStartWire |
Boolean |
Default=False
Only effective if AutoWireEnabled is False. Selects mode whereby a wire is started when the cursor is brought close to a pin or wire termination. This mode is on automatically when AutoWireEnabled is True |
Options dialog |
||||||
AutoWireEnabled | Boolean |
Default=True
Smart wiring is on if this is True |
Options dialog |
||||||
AWAllowRouteThruConnected | Boolean |
Default=True
Controls whether the smart wire algorithm is allowed to route wires through existing wires that connect to the destination or target |
Options dialog |
||||||
AxisPrintWidth | Numeric |
Default = 0.5
Width of printed axis in mm. See also CurvePrintWidth and GridPrintWidth |
Options dialog |
||||||
AutoSaveInterval |
Numeric | Default=0 meaning disabled. Interval in minutes for which the session is automatically saved in order to recover from an unexpected program exit | Options dialog | ||||||
BiasAnnoPrecision | Numeric |
Default=6
Precision of values displayed for schematic DC bias annotation |
Options dialog |
||||||
BiScriptDir | Text |
This is the first location that SIMetrix searches for scripts. See File Locations section of Options dialog above for more info. |
Options dialog |
||||||
BuildAssociations | Text |
Default=ask
See Auto Configuration Options |
|||||||
BuildModelLibs | Text |
Default=ifempty
See Auto Configuration Options |
|||||||
BuildPreferenceSettings | Text |
Default=askmigrate
See Auto Configuration Options |
|||||||
BuildSymbolLibs | Text |
Default=ifempty
See Auto Configuration Options |
|||||||
CachePathSymbols unsupported | Boolean |
Default=false
If true, SIMetrix will cache symbolic paths |
|||||||
ComponentExtension |
Text |
Default=sxcmp
File extension for schematic component files |
Options dialog |
||||||
CursorDisplay | Text |
Default = Graph. Controls initial graph cursor readout display.
|
Options dialog |
||||||
CurvePrintWidth | Numeric | Default = 0.5mm Width of printed graph curves in mm. See also GridPrintWidth. |
Options dialog |
||||||
CurveWeight | Numeric | Default = 1 Sets the line width in pixels of graph curves. Note that although widths greater than 1 are clearer they normally take considerably longer to draw. This does however depend on the type of adapter card and display driver you are using. |
Options dialog |
||||||
DataExtension | Text |
Default=sxdat;dat
Default file extension for data files |
Options dialog |
||||||
DataGroupDelete | Text | Default = OnStart Determines when temporary simulation data is deleted. Possible values, Never, OnStart, OnClose and OnDelete. See Graph/Probe/Data Analysis for details. |
Options dialog |
||||||
DefaultLib | Text |
Default=%SHAREPATH%/SymbolLibs/default.sxslb
Name and location of default symbol library |
|||||||
DefaultPersistence |
Default=0
Sets the number of curves that are kept for graph fixed probes. '0' means that all curves are kept. '1' means that only 1 is kept at a time. |
Options dialog |
|||||||
DevConfigFile | Text |
Default=%SHAREPATH%/DeviceConfig.cfg
Name and location of device configuration file. See Simulator Reference Manual for details |
|||||||
DigAxisHeight | Numeric | Default = 8.0mm Height of digital axis in mm. (Screens are typically 75pixels/inch) |
Options dialog |
||||||
DisableCurveDataCompression |
bool | Default=FALSE Set to TRUE to disable curve point compression. This generally speeds up graph drawing but can introduce minor artefacts | No | ||||||
DisplaySimProgressMessage |
Boolean |
Default=False
If true, a message will be displayed in the command shell indicating the start and end of a simulation |
|||||||
EchoOn | Boolean | When set, all commands are echoed to the command shell message window. This is used primarily for script debugging. |
Options dialog |
||||||
EnableFileChangeWatcher |
bool | Default=TRUE The GUI monitors changes to files and prompts the user to reload when changes are detected. Set this to FALSE to disable | No | ||||||
EnableFileChangeWatcher FileView |
bool | Default=TRUE The file viewer monitors changes to files and updates if changes are detected. Set to FALSE to disable this behaviour | No | ||||||
EnableLWEditMenu |
bool | Default=FALSE Enables the schematic popup menu | which edits the length, width and multiplier (M) for MOSFETs used in IC design|||||||
ExportRawFormat |
Text | Default = SPICE3 Possible values, SPICE3, SPECTRE and OTHER. Controls format of raw output. See Exporting SPICE3 Raw Files | No | ||||||
ForceGlobalHash |
Boolean |
Default=false
In the simulator, any node name found in a subcircuit that starts with a '#' accesses a top level node of the same name but without the '#'. E.g. #VCC in a subcircuit connects to VCC at the top level. If this option is set, the '#' is not stripped, so #VCC in a subcircuit connects to #VCC at the top level. |
|||||||
GlobalCatalog unsupported | Text |
Default=%SHAREPATH%/devdb/all.cat
Path of global catalog file. (usually referred to as ALL.CAT). |
|||||||
GraphExtension | Text |
Default=sxgph
File extension used for graph files |
Options dialog |
||||||
GraphLegendMaximum HeightProportion |
real | Default=0.25 Maximum height of the graph legend window as a proportion of the graph window height | |||||||
GridPrintWidth |
Numeric | Default = 0.3mm Width of printed graph grid lines in mm. See also CurvePrintWidth |
Options dialog |
||||||
GroupPersistence | Numeric | Default = 3 Sets the number of groups that are kept before being deleted. See Plotting the Results from a Previous Simulation | No | ||||||
GuiEditPropertyEnabled | Boolean |
Default=false
If set, allows visible properties in the schematic to be edited using GUI actions. |
Options dialog |
||||||
HideSchematicGrid | Boolean | If set, the schematic grid will be suppressed |
Options dialog |
||||||
HistoAdvancedStats |
bool | Default=FALSE Display advanced statistics in histogram plots | Performance analysis dialog | ||||||
HighlightIncrement |
Numeric |
Default = 1
Highlighted graph curves are thicker than normal curves by the amount specified by this option |
No | ||||||
HistoCurveStyle | Text |
Default=stepped
Sets histogram curve style |
Options dialog |
||||||
InitSchematicSimulator |
Text |
Default=SIMetrix
Simulator mode for new schematic. If set to SIMPLIS, all schematics will start in SIMPLIS mode. Otherwise they start in SIMetrix mode |
Options dialog |
||||||
InterpOrder | Numeric |
Default=2
Sets interpolation order for the FFT calculation used for distortion measurements |
|||||||
InterpPts | Numeric |
Default=1024
Sets number of interpolated points for the FFT calculation used for distortion measurements |
|||||||
InvertCursors | Boolean |
Default=false
If true, schematic and graph mouse cursors are modified to be suitable for use on a black background |
|||||||
LibraryDiagnostics | Text |
Default = Full
Possible values, Partial, None and Full. Affects progress information displayed during model library searching. |
Options dialog |
||||||
LicenseDisableFast Checkout | Boolean |
Default=false
Affects network licenses only. If set, the license checkout process may take longer delaying the time it takes SIMetrix to start. |
|||||||
LogicDefExtension | Text |
Default=ldf
File extension used for logic definition files |
Options dialog |
||||||
MaxHighlightColours |
Numeric |
Default=4
Maximum number of different colours used for schematic highlighting |
|||||||
MaxVectorBufferSize | Numeric | Default=32768 See the Simulator Reference Manual for a full explanation | |||||||
MinGridHeight | Numeric | Minimum allowed height of graph grid |
Options dialog |
||||||
MinorGridPrintWidth | Numeric |
Default=0.05
Print width in mm of graph's minor grid |
Options dialog |
||||||
ModelExtension | Text |
Default=lb;lib;mod;cir
File extensions used for model files |
Options dialog |
||||||
MRUSize | Numeric | Default = 4 Number of items in File | Reopen menu. |
Options dialog |
||||||
NewModelLifetime |
Numeric |
Default=30
Number of days that user installed models remain displayed in the '* Recently Added Models *' model library browser category |
|||||||
NoEditPinNamesWarning
unsupported |
Boolean |
Default=false
If true, the warning given when using the Edit Pin Names button in the associate models dialog box is inhibited |
|||||||
NoHierarchicalHighlighting | Boolean |
Default=false
If set hierarchical schematic highlighting is disabled. That is, if you highlight some part of a hierarchical schematic, only that schematic will be highlighted with no propagation to parent or child schematic |
|||||||
NoKeys |
Boolean | If on, the default key definitions will be disabled. Note this will not take affect until the next session of SIMetrix. |
Options dialog |
||||||
NoMenu | Boolean | If on, the default menu definitions will be disabled and no menu bar will appear. This will not take affect until the next session of SIMetrix. |
Options dialog |
||||||
NoStopOnError | Boolean | If disabled, scripts and multi-command lines (i.e. several commands on the same line separated by ';') are aborted if any individual command reports an error. |
Options dialog |
||||||
NoStopOnUnknownParam | Text |
Specifies action to be taken in the event of an unknown parameter being encountered in a .MODEL statement. Choices are:
TRUE: No action taken, simulation continues normally FALSE: An error will be raised and the simulation will abort WARN: A warning will be displayed but the simulation will continue This will be overridden by a .OPTIONS setting of the same name. Refer to Simulator Reference Manual/Command Reference/.OPTIONS for details |
Options dialog |
||||||
OmitAsciiRevision unsupported |
Boolean |
Default=false
If true, the revision value is not written to ASCII schematic files. For backward compatibility. |
No | ||||||
PartSelShowSimplisModels |
Boolean |
Default=False
If true, model library parts will show directly in the part selector in SIMPLIS mode |
No | ||||||
PartSelShowSimetrixModels | Boolean |
Default=True
If true, model library parts will show directly in the part selector in SIMetrix mode |
No | ||||||
PassUnresTemplate unsupported | Boolean |
Default=false
If true, unresolved template values in netlists will be passed literally. Default behaviour is no output |
No | ||||||
Precision | Numeric |
Default = 10
Precision of numeric values displayed using Show command. |
No | ||||||
PrintOptions | Text | Options set in print dialog |
Print dialog |
||||||
PrintWireWidth | Numeric | Default=5 Width in pixels of schematic wires when printed | No | ||||||
ProbeFlushOnUpdate | Boolean |
Default=false
It is not usual to need to set this option. Simulation data is buffered for performance reasons but this buffering can interfere with the incremental updates needed for fixed probes. Usually SIMetrix deals with this problem automatically but this is not guaranteed to work in all cases. In such situations, fixed probes or .GRAPH statements may not incrementally update correctly. Setting this option may rectify this. |
|||||||
ProbeStartDelay | Numeric | Default = 1 Delay after start of simulation run before fixed probe graphs are first opened. |
Options dialog |
||||||
ProbeUpdatePeriod | Numeric | Default = 0.5 seconds Update period for fixed probe graphs |
Options dialog |
||||||
PSpiceIniPath | Text | Path of PSPICE.INI file needed for the PSpice 'Schematics' translator. |
Options dialog |
||||||
RebuildConfig | Boolean |
Default=true
See Auto Configuration Options |
No | ||||||
RepeatPlace | Text |
Default = Toolbar
Controls when schematic placement is repeated. Possible values, Always, Toolbar (toolbar symbols only) and Never. |
Options dialog |
||||||
SchematicReadOnly |
Boolean |
Default=false
If set all schematics are opened in read only mode |
No | ||||||
SchemDoubleClickScript | Text |
Default=on_schem_double_click /ne
Script that is called when a double click action is detected in the schematic. Only active if SchematicEditMode= NoSnap |
|||||||
ScriptDir | Text |
Default=%SXDOCSPATH%/Scripts
%SXDOCSPATH% is "My Documents/SIMetrix" Directory used to search for scripts and symbol files if not found in the current directory. Changes to this option do not take effect until next session. |
Options dialog |
||||||
ScriptExtension | Text |
Default=sxscr
File extension used for scripts |
Options dialog |
||||||
ShellCommandProcessor | Text | String used to launch command processor when /command supplied with "Shell" script command. See Shell command in the Script Reference manual for more details | |||||||
SHOWWELCOMEPAGE | Boolean | Default=true. If set a welcome page will be displayed on first start | Welcome page | ||||||
SimDataGroupDelete | Text |
Default=Never
Same as DataGroupDelete when simulator is run independently. I.e. not called from the front end |
No | ||||||
SIMPLISPath | Text |
Default=%EXEPATH%/simplis.exe
Path of SIMPLIS binary |
No | ||||||
SnapshotExtension | Text |
Default=sxsnp
File extension used for snapshot files |
|||||||
SplitGraphWindows |
Boolean | Default=true. If set, the layout is automatically split when creating a graph window | No | ||||||
StartUpDir |
Text | Current directory set at start of session. |
Options dialog |
||||||
StartUpFile | Text | Default = Startup.SXSCR Script that is automatically run at start of each session. |
Options dialog |
||||||
StatusUpdatePeriod | Numeric | Default = 0.2 seconds Minimum delay in seconds between updates of simulator status window during run. | No | ||||||
SymbolExtension | Text |
Default=sxslb;slb
File extension used for symbol files |
|||||||
SymbolsDir |
Text |
Default=%SHAREPATH%/SymbolLibs
Path of directory where system symbol libraries are located. |
Option dialog | ||||||
SystemStyle |
Text | Default=LightStyle.qss. Sets the style sheet that defines the user interface style. May be set to DarkStyle.qss or custom generated style sheet placed in support\ ui | |||||||
TempDataDir | Text |
Default = %TEMPPATH%/
SIMetrixTempData
See Default Configuration Location for definition of %TEMPPATH% Directory where temporary simulation data files are placed. |
Options dialog |
||||||
TextExtension | Text | File extension used for text files | |||||||
TotalVectorBufferSize | Numeric | See the Simulator Reference Manual for a full explanation | |||||||
TitleBlockDefaultAuthor |
Text | The default authour for title blocks | Title block interface | ||||||
TitleBlockDefaultCompany | Text | The default company name for title blocks | Title block interface | ||||||
TitleBlockDefaultLogoPath | Text | The path of the default logo for title blocks. Should be a bitmap file such as .jpg, .png, .bmp or .gif | Title block interface | ||||||
ToolBarIconSize |
Numeric | Default = 20. Size of toolbar icons in pixels. Takes effect on restart | No | ||||||
TranscriptErrors |
Boolean |
Default=false
If true, incorrectly typed commands will be entered in the history box. (The drop down list in the command line that shows previously entered commands) |
|||||||
UndoBufferSize | Numeric |
Default = 10
Number of levels of schematic undo. See Creating a Schematic |
Options dialog |
||||||
UpdateClosedSchematics | Boolean | Allows SIMetrix to write to closed schematic if required. See Closed Schematics | |||||||
UpdateCurvesNoDeleteOld | Boolean |
Default=false
If true, old curves are not deleted when using the Update Curves feature. |
Plot | Update Curve Settings | ||||||
UpdateCurvesNoFixSelected | Boolean |
Default=false
If true update includes selected curves when using the Update Curves feature |
Plot | Update Curve Settings | ||||||
UseAltGraphPrintStyles | Boolean | Determines method of differentiating curves on monochrome hardcopies. See Graph Printing |
Options dialog |
||||||
UseGreekMu | Boolean |
Default=false
If true, the 'u' used to denote 10e-6 will be displayed as a greek $\mu$ in graph axis labels |
No | ||||||
UserCatalog unsupported |
Text |
Default=%sxappdatapath%/user_v2
Location and base name without extension of the user catalog file |
No | ||||||
UseLocalHelp | Boolean | If set, the help system will use locally stored content. Note that the local content must be installed for this to work. Menu | will automatically set this option and install local content if needed.|||||||
UserScriptDir | Text | Alternative location for user scripts. See Script Reference Manual/Script Language/Executing Scripts for more information | No | ||||||
UserSymbolsDir | Text | Path of directory where the user's symbol libraries are stored. |
Options dialog |
||||||
UserSystemSymbolDir | Text |
Default=%sxappdatapath%/SysSymbols
Location of symbol libraries containing edits to system symbols |
No | ||||||
UseSmallGraphCursor | Boolean |
Default=false
If true, a small graph cursor will be used instead of the full crosshair |
Cursors | Cursor Style | ||||||
VideoBufferTotalSize |
Numeric | Default=100000000 (100MBytes). The total memory allowed to be used for video buffers. The bitmap image of each schematic and graph window is buffered in memory. This allows for fast redraw when tabs are switched or when a window is exposed. Without this buffering, the windows need to be redrawn which in the case of graphs can be time consuming. The buffers consume memory and this setting specifies how much memory may be allowed to be used for the buffers (that is all buffers together, not each one). If all the buffers needed exceed this memory allowance, some windows will be released meaning that a redraw will be needed when that window needs to be displayed. | No | ||||||
VlDataPath |
Text |
Default=%SXAPPDATAPATH%/veriloghdl
Location of Verilog-HDL files. Currently only the cache data is stored here |
|||||||
VlModuleCacheSize | Numeric |
Default=1000
Maximum number of cache entries for Verilog-HDL module info cache |
|||||||
WarnSubControls | Boolean |
Default=false
If true, a warning will be issued if unexpected simulator commands are found in subcircuits. |
No | ||||||
WorkingCatalog unsupported |
Text |
Default=%sxappdatapath% /devdb/working/out.cat
Path of working catalog file.(OUT.CAT) |
No |
The following options set colours for text editor elements. All of these can be set in the Customisation sheet in the options dialog. See menu .
Option name | Editor | Element |
---|---|---|
AsciiFileEditorDoubleQuoteStringColour | Ascii File Editor | Double quoted string |
AsciiFileEditorSingleQuoteStringColour | Ascii File Editor | Single quoted string |
AsciiFileEditorSubTypesColour | Ascii File Editor | Sub types |
AsciiFileEditorTypesColour | Ascii File Editor | Types |
AsciiFileEditorValuesColour | Ascii File Editor | Values |
LogicDefinitionEditorCommentColour | Logic Definition | comment colour |
LogicDefinitionEditorKeywordColour | Logic Definition | keyword colour |
NetlistEditorCommentColour | Netlist editor | comment colour |
NetlistEditorDoubleQuoteStringColour | Netlist editor | Double quoted string colour |
NetlistEditorInstanceColour | Netlist editor | Instance colour |
NetlistEditorKeywordColour | Netlist editor | keyword colour |
NetlistEditorSingleQuoteStringColour | Netlist editor | Single quoted string colour |
NetlistEditorSubCircuitColour | Netlist editor | Subcircuit colour (.SUBCKT and .ENDS) |
ScriptEditorBIScriptColour | Script Editor | Built-in script colour |
ScriptEditorCommandColour | Script Editor | Command colour |
ScriptEditorCommentColour | Script Editor | Comment colour |
ScriptEditorDoubleQuotedStringColour | Script Editor | double quoted string colour |
ScriptEditorFunctionColour | Script Editor | Function colour |
ScriptEditorKeywordColour | Script Editor | keyword colour |
ScriptEditorStringColour | Script Editor | string colour |
TextEditorBackgroundColour | Plain text editor | background colour |
TextEditorFontColour | Plain text editor | Text colour |
TextEditorHighlightColour | Plain text editor | highlighted colour |
VerilogAEditorAnalogOperatorColour | Verilog-A editor | Analog operator colour |
VerilogAEditorDoubleQuoteColour | Verilog-A editor | String colour |
VerilogAEditorIntegerColour | Verilog-A editor | Integer colour |
VerilogAEditorKeywordColour | Verilog-A editor | Keyword colour |
VerilogAEditorMultilineCommentColour | Verilog-A editor | Multi-line comment colour |
VerilogAEditorPreProcessorColour | Verilog-A editor | Pre-processor colour |
VerilogAEditorRealColour | Verilog-A editor | Real value colour |
VerilogAEditorRegularFunctionsColour | Verilog-A editor | Function colour |
VerilogAEditorSingleLineCommentColour | Verilog-A editor | Singe line comment colour |
VerilogAEditorSystemFunctionsColour | Verilog-A editor | System function colour |
VerilogHDLEditorDoubleQuoteStringColour |
Verilog-HDL editor |
String colour |
VerilogHDLEditorKeywordColour | Verilog-HDL editor | Keyword colour |
VerilogHDLEditorMultipleLineCommentColour |
Verilog-HDL editor |
Multi-line comment colour |
VerilogHDLEditorSingleLineCommentColour |
Verilog-HDL editor |
Single line comment colour |
The following options set colours for various elements. All of these can be set in the Customisation sheet in the options dialog. See menu .
Option name | Editor | Element |
---|---|---|
ShellInputActiveHighlightColour | Command Shell Input | Active highlight |
ShellInputBackgroundColour | Command Shell Input | Background |
ShellInputHighlightedTextColour | Command Shell Input | Highlighted text |
ShellInputInactiveHighlightColour | Command Shell Input | Inactive highlight |
ShellInputTextColour | Command Shell Input | Input text |
ShellOutputActiveHighlightColour |
Command Shell Output |
Active highlight |
ShellOutputBackgroundColour |
Command Shell Output |
Background |
ShellOutputHighlightedTextColour |
Command Shell Output |
Highlighted text |
ShellOutputInactiveHighlightColour |
Command Shell Output |
Inactive highlight |
ShellOutputTextColour |
Command Shell Output |
Input text |
PartSelectorBackgroundColour | Part selector | Background colour |
PartSelectorTextColour | Part selector | Text colour |
GraphColourText | Graph | Text Colour (default graph text colour) |
GraphColourSelectedText | Graph | Selected Text Colour |
GraphColourCaption | Graph | Caption Colour |
GraphColourFreeText | Graph | Free Text Colour |
GraphColourTextBoxText | Graph | Text Box Text Colour |
GraphColourTextBoxBG | Graph | Text Box Background |
GraphColourLegendBox | Graph | Legend Box Text Colour |
GraphColourCurveMarkerText | Graph | Curve Marker Text Colour |
GraphColourCurveMarker | Graph | Curve Marker Line Colour |
GraphColourRectangle | Graph | Zoom Box Colour |
GraphColourCrossHair | Graph | Cursor Colour |
GraphColourMajorGrid | Graph | Major Grid |
GraphColourMinorGrid | Graph | Minor Grid |
GraphColourBackground | Graph | Background |
GraphColourAxis | Graph | Axis |
GraphColourSelectedAxis | Graph | Selected Axis |
GraphColourHighlightedCurve | Graph | Highlighted Curve |
GraphColourCursorDimension | Graph | Cursor Dimension |
GraphColourCursorDimensionText | Graph | Cursor Dimension Text |
GraphColourCurve_1 | Curves | Curve 1 Colour |
GraphColourCurve_2 | Curves | Curve 2 Colour |
GraphColourCurve_3 | Curves | Curve 3 Colour |
GraphColourCurve_4 | Curves | Curve 4 Colour |
GraphColourCurve_5 | Curves | Curve 5 Colour |
GraphColourCurve_6 | Curves | Curve 6 Colour |
GraphColourCurve_7 | Curves | Curve 7 Colour |
GraphColourCurve_8 | Curves | Curve 8 Colour |
GraphColourCurve_9 | Curves | Curve 9 Colour |
GraphColourCurve_10 | Curves | Curve 10 Colour |
GraphColourCurve_11 | Curves | Curve 11 Colour |
GraphColourCurve_12 | Curves | Curve 12 Colour |
GraphColourCurve_13 | Curves | Curve 13 Colour |
GraphColourCurve_14 | Curves | Curve 14 Colour |
GraphColourCurve_15 | Curves | Curve 15 Colour |
GraphColourCurve_16 | Curves | Curve 16 Colour |
GraphColourCurve_17 | Curves | Curve 17 Colour |
GraphColourCurve_18 | Curves | Curve 18 Colour |
GraphColourCurve_19 | Curves | Curve 19 Colour |
GraphColourCurve_20 | Curves | Curve 20 Colour |
The following options set default file extensions. See Options dialog for more details.
Option name | Default value | Description |
---|---|---|
AsciiFileEditorExtension | sxsch;sxslb;sxcmp | ASCII schematic and symbol files |
ComponentExtension | sxcmp | Schematic component files |
DataExtension | sxdat;dat | Data files |
GraphExtension | sxgph | Graph binary files |
LogicDefExtension | ldf | Arbitrary block logic definition files |
ModelExtension | lb;lib;mod;cir | SPICE model files |
NetlistExtension | net;cir;deck;out | Netlist files |
SchematicExtension | sxsch;sch | Schematic files |
ScriptExtension | sxscr;txt | Scripts |
SnapshotExtension | sxsnp | Simulator snapshot files |
SymbolExtension | lib | Binary symbol files |
TextExtension | txt;net;cir;mod;ldf;sxscr;lib;lb;cat | Text files |
VerilogAExtension | va;vams | Verilog-A files |
VerilogHDLExtension | v | Verilog-HDL files |
The buttons displayed on each of the standard toolbars are defined with an option variable - that is one for each toolbar. The value of the option consists of a series of semi-colon delimited button names. A complete list of button names and full information concerning user defined toolbars can be found in the Script Reference Manual/Applications/Creating Modifying Toolbars. The toolbar option variable names are listed below.
Option name | Description |
---|---|
ComponentButtons | Schematic parts in SIMetrix mode |
SIMPLISComponentButtons | Schematic parts in SIMPLIS mode |
SchematicMainButtons | Schematic main toolbar |
SchematicFileButtons | Schematic file operations toolbar |
SchematicProbeButtons | Schematic probe toolbar |
SymbolMainButtons | Symbol editor toolbar |
SymbolFileButtons | Symbol editor file operations toolbar |
GraphMainButtons | Graph window toolbar |
|