» SIMPLIS DVM Test Report Overview

General
Schematic 8.2_LLC Closed Loop.sxsch
Testplan dvm_advanced.testplan
Original Testplan Filename 8.2_efficiency_and_loop_characteristics.testplan
Date / Time 2015-12-10 6:06 PM
Report Directory measure_loop_param
Log File dvm_advanced.log
# of Tests Run 47 of 47 (42 Passed, 5 Skipped)
Total Time 10m 39s
Design Specifications
Circuit Name DVM_LLC_Closed_Loop
Description 120W LLC Converter
Input 1 380.000 V (360 V to 400 V)
Output 1 24 V (±5%) @ 5 A
Switching Frequency 85kHz
Excel-compatible Results
Scalar Results dvm_advanced_table_scalars.txt
Spec Results dvm_advanced_table_specs.txt
Statistic Results dvm_advanced_table_statistics.txt
Statistic Specs dvm_advanced_table_statspecs.txt
Overview Graphs
Efficiency
VIN Maximum
VIN Minimum
VIN Nominal
SXGPH File global_2521.sxgph
Source Test Efficiencyand Loop Characterization|Efficiency Summary
Gain Crossover Frequency
VIN Maximum
VIN Minimum
VIN Nominal
SXGPH File global_2528.sxgph
Source Test Efficiencyand Loop Characterization|Gain Crossover Frequency
Gain Margin
VIN Maximum
VIN Minimum
VIN Nominal
SXGPH File global_2535.sxgph
Source Test Efficiencyand Loop Characterization|Gain Margin
Phase Margin
VIN Maximum
VIN Minimum
VIN Nominal
SXGPH File global_2542.sxgph
Source Test Efficiencyand Loop Characterization|Phase Margin
Switching Frequency
VIN Maximum
VIN Minimum
VIN Nominal
SXGPH File global_2549.sxgph
Source Test Efficiencyand Loop Characterization|Switching Frequency
Test 1 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|5% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\5% Load\report.txt.html
Status PASS
Test Time 14s
Test 2 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|10% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\10% Load\report.txt.html
Status PASS
Test Time 14s
Test 3 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|15% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\15% Load\report.txt.html
Status PASS
Test Time 14s
Test 4 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|20% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\20% Load\report.txt.html
Status PASS
Test Time 14s
Test 5 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|25% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\25% Load\report.txt.html
Status PASS
Test Time 14s
Test 6 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|30% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\30% Load\report.txt.html
Status PASS
Test Time 13s
Test 7 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|35% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\35% Load\report.txt.html
Status PASS
Test Time 14s
Test 8 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|40% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\40% Load\report.txt.html
Status PASS
Test Time 14s
Test 9 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|50% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\50% Load\report.txt.html
Status PASS
Test Time 13s
Test 10 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|60% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\60% Load\report.txt.html
Status PASS
Test Time 15s
Test 11 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|70% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\70% Load\report.txt.html
Status PASS
Test Time 14s
Test 12 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|80% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\80% Load\report.txt.html
Status PASS
Test Time 14s
Test 13 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|90% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\90% Load\report.txt.html
Status PASS
Test Time 14s
Test 14 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Nominal|100% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Nominal\100% Load\report.txt.html
Status PASS
Test Time 14s
Test 15 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|5% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\5% Load\report.txt.html
Status PASS
Test Time 14s
Test 16 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|10% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\10% Load\report.txt.html
Status PASS
Test Time 14s
Test 17 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|15% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\15% Load\report.txt.html
Status PASS
Test Time 14s
Test 18 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|20% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\20% Load\report.txt.html
Status PASS
Test Time 14s
Test 19 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|25% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\25% Load\report.txt.html
Status PASS
Test Time 14s
Test 20 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|30% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\30% Load\report.txt.html
Status PASS
Test Time 14s
Test 21 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|35% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\35% Load\report.txt.html
Status PASS
Test Time 14s
Test 22 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|40% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\40% Load\report.txt.html
Status PASS
Test Time 14s
Test 23 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|50% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\50% Load\report.txt.html
Status PASS
Test Time 14s
Test 24 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|60% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\60% Load\report.txt.html
Status PASS
Test Time 14s
Test 25 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|70% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\70% Load\report.txt.html
Status PASS
Test Time 14s
Test 26 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|80% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\80% Load\report.txt.html
Status PASS
Test Time 14s
Test 27 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|90% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\90% Load\report.txt.html
Status PASS
Test Time 14s
Test 28 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Maximum|100% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Maximum\100% Load\report.txt.html
Status PASS
Test Time 14s
Test 29 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|5% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\5% Load\report.txt.html
Status PASS
Test Time 14s
Test 30 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|10% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\10% Load\report.txt.html
Status PASS
Test Time 13s
Test 31 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|15% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\15% Load\report.txt.html
Status PASS
Test Time 14s
Test 32 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|20% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\20% Load\report.txt.html
Status PASS
Test Time 13s
Test 33 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|25% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\25% Load\report.txt.html
Status PASS
Test Time 13s
Test 34 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|30% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\30% Load\report.txt.html
Status PASS
Test Time 14s
Test 35 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|35% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\35% Load\report.txt.html
Status PASS
Test Time 13s
Test 36 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|40% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\40% Load\report.txt.html
Status PASS
Test Time 14s
Test 37 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|50% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\50% Load\report.txt.html
Status PASS
Test Time 13s
Test 38 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|60% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\60% Load\report.txt.html
Status PASS
Test Time 13s
Test 39 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|70% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\70% Load\report.txt.html
Status PASS
Test Time 14s
Test 40 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|80% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\80% Load\report.txt.html
Status PASS
Test Time 13s
Test 41 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|90% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\90% Load\report.txt.html
Status PASS
Test Time 14s
Test 42 of 47top ▲
Test Label Efficiency and Loop Characterization|Vin Minimum|100% Load
Simulator simplis
Test Report Efficiencyand Loop Characterization\Vin Minimum\100% Load\report.txt.html
Status PASS
Test Time 13s
Test 43 of 47top ▲
Test Label Efficiency and Loop Characterization|Efficiency Summary
Simulator N/A
Test Report Efficiencyand Loop Characterization\Efficiency Summary\report.txt.html
Status SKIP
Test Time 4s
Test 44 of 47top ▲
Test Label Efficiency and Loop Characterization|Gain Crossover Frequency
Simulator N/A
Test Report Efficiencyand Loop Characterization\Gain Crossover Frequency\report.txt.html
Status SKIP
Test Time 4s
Test 45 of 47top ▲
Test Label Efficiency and Loop Characterization|Gain Margin
Simulator N/A
Test Report Efficiencyand Loop Characterization\Gain Margin\report.txt.html
Status SKIP
Test Time 4s
Test 46 of 47top ▲
Test Label Efficiency and Loop Characterization|Phase Margin
Simulator N/A
Test Report Efficiencyand Loop Characterization\Phase Margin\report.txt.html
Status SKIP
Test Time 3s
Test 47 of 47top ▲
Test Label Efficiency and Loop Characterization|Switching Frequency
Simulator N/A
Test Report Efficiencyand Loop Characterization\Switching Frequency\report.txt.html
Status SKIP
Test Time 3s