DVM - Design Verification Module

Short Circuit Load

The Short Circuit Load subcircuit models the application of a short circuit at a user-defined time point. Using the recover argument, you can remove the short circuit and test the recovery of the circuit. This load is used in the built-in testplans for the ShortCkt() Test Objective.

Other similar loads include:

In this Topic Hide

Model Name

Short Circuit Load

Simulator

This device is compatible with both the SIMetrix and SIMPLIS simulators.

Parts Selector
Menu Location

  • DVM ▶Loads ▶DVM Output Load - 2 Terminal
  • DVM ▶Loads ▶DVM Output Load - 3 Terminal
  • DVM ▶Loads ▶DVM Output Load - 4 Terminal

Symbol Library

None - the symbol is automatically generated when placed or edited.

Model File

SIMPLIS_DVM_ADVANCED.lb

Subcircuit Name
  • SIMPLIS_DVM_ADVANCED_LOAD_2T_RES_SHORTCKT
  • SIMPLIS_DVM_ADVANCED_LOAD_3T_RES_SHORTCKT
  • SIMPLIS_DVM_ADVANCED_LOAD_4T_RES_SHORTCKT
Symbols
Schematic - 2 Terminal
Schematic - 3 Terminal
Schematic - 4 Terminal

Parameters

The following table explains the parameters used in the short circuit load subcircuit..

Parameter Name Default Data Type Range Units Parameter Description

LOAD_NAME

LOAD String n/a n/a

Name of the DVM load. This name cannot contain spaces.

LOAD_RESISTANCE

2.00667 Real min: 0 Ω

The resistance value which models the starting current of the load.

PULSE_WIDTH

200u Real min: 0 s The pulse width of the short circuit in seconds.

SHORTCKT_LOAD_RESISTANCE

10m Real min: >0 Ω The resistance of the short circuit condition.

TIME_DELAY

10u Real min: 0 s

The time delay before the short circuit initiates.

© 2015 simplistechnologies.com | All Rights Reserved