                  n1
                 | 
                Node 1 | 
              
              
                | 
                  n2
                 | 
                Node 2 | 
              
              
                | 
                  model_name
                 | 
                (Optional) Name of model. Must begin with a letter but can contain any character except whitespace and period '.' | 
              
              
                | 
                  value
                 | 
                Capacitance (Farads) | 
              
              
                | 
                  initial_condition
                 | 
                
                  Initial voltage if UIC specified on .TRAN statement.
                 | 
              
              
                | 
                  local_temp
                 | 
                Capacitor temperature (???MATH???°???MATH???C) | 
              
              
                | 
                  tc1
                 | 
                First order temperature coefficient | 
              
              
                | 
                  tc2
                 | 
                Second order temperature coefficient | 
              
              
                | 
                  vc1
                 | 
                First order voltage coefficient | 
              
              
                | 
                  vc2
                 | 
                Second order voltage coefficient | 
              
              
                | 
                  BRANCH
                 | 
                
                  May be 0 or 1. 0 is the default. This parameter determines the internal formulation of the capacitor and affects how the IC parameter is implemented. When BRANCH=0, the capacitor looks like an open circuit during the DC operating point and the IC parameter has no effect unless UIC is specified for a transient analysis. If BRANCH=1, the capacitor looks like a voltage source during dc operating point with a magnitude equal to the value of the IC parameter. BRANCH=1 makes it possible to specify circuit startup conditions. See Alternative Initial Condition Implementations for an example.
                 | 
              
              
                | 
                  mult
                 | 
                
                  Device multiplier. Equivalent to putting mult devices in parallel.
                 | 
              
              
                | 
                  dtemp
                 | 
                
                  Differential temperature. Similar to local_temp but is specified relative to circuit temperature. If both TEMP and DTEMP are specified, TEMP takes precedence.
                 | 
              
              
                | 
                  esr
                 | 
                
                  Effective series resistance. If non-zero (the default value), a resistor of value esr will be connected in series with the capacitor. The resulting implementation of a series RC network is more efficient and offers better convergence than using a separate R and C. This is especially the case if the capacitor has a high value and is non-grounded.
                  
                  
Important: this resistor is noiseless; if the noise in the ESR is important in your design, you should use a separate resistor and omit this parameter in the capacitor.
                 |