In chapter 2, you created a synchronous buck converter schematic and changed the component
         values to suit this particular design. In this section of the tutorial, you will learn to
         configure and run all three SIMPLIS analysis types:
      
	
         - A basic Transient simulation which is similar to the transient analysis in other
            simulators but much faster.
- A Periodic Operating Point (POP) analysis which finds the steady-state operating
            point of the buck converter. The POP analysis requires you to add a POP trigger symbol
            to identify which node defines the analysis period for the Periodic Operating Point
            analysis.
- An AC analysis in which you add a modulator, AC injection source, and MOSFET
            gate driver and then rewire the schematic. You will also find the control-to-output, or
            plant response, of the converter.
After you complete these analyses, your schematic should look like this:
 
      
         ▲ back to top