Opens a dialog box to allow the user to plot a bus.
        
        
            Arguments
        
        
            
                
                
                
                
                
                
                    
                        | Number | Type | Compulsory | Default | Description | 
                    
                        | 1 | string array | Yes |  | Initial values | 
                    
                        | 2 | string | No |  | options | 
                
            
        
        
            Argument 1
        
        
            String array of length up to 9. Elements defined in the following table:
            
                
                    
                    
                    
                    
                        
                            | Index | Description | Default | 
                        
                            | 0 | Bus name | " | 
                        
                            | 1 | Bus start index | 0 | 
                        
                            | 2 | Bus end index | 0 | 
                        
                            | 3 | Display type: 
                                    
                                        
                                            
                                                
                                                    | '0' | Decimal |  
                                                    | '1' | Hexadecimal |  
                                                    | '2' | Analog waveform |  
                                                    | '3' | Binary |  | '0' | 
                        
                            | 4 | Hold invalid: 
                                    
                                        
                                            
                                                
                                                    | 'TRUE' | Hold invalid ON |  
                                                    | 'FALSE' | Hold invalid off |  | 'FALSE' | 
                        
                            | 5 | Scale factor | '1.0' | 
                        
                            | 6 | Offset '0.0' |  | 
                        
                            | 7 | Units |  | 
                        
                            | 8 | Items used to load 'Units' combo box separated by '|' |  | 
                        
                            | 9 | Analog threshold lower |  | 
                        
                            | 10 | Analog threshold upper |  | 
                        
                            | 11 | Axis type: 
                                    
                                        
                                            
                                                
                                                    | '0' | Auto select |  
                                                    | '1' | Use separate Y-axis |  
                                                    | '2' | Use separate grid |  
                                                    | '3' | Digital |  |  | 
                        
                            | 12 | Axis name |  | 
                        
                            | 13 | Use separate graph? |  | 
                        
                            | 14 | Graph name |  | 
                    
                
            
        
            Argument 2
        
        
            Options. Currently just one. If set to 'noProbeOptions', the Probe Options sheet will be
              hidden.
        
        
            Returns
        
        
            Return type: string array
        
        
            String array with the same length as the input. Each field holds the value selected by
            the user. Note that field index 8 does not currently output a meaningful value and
            should be ignored.