Returns value of schematic window property value.
| Number | Type | Compulsory | Default | Description | 
| 1 | string | Yes | Property name | |
| 2 | string | No | Currently displayed | Schematic path | 
| 3 | number | No | Schematic handle | 
| 'Path' | Read-only. File system path name of schematic | 
| 'RootPath' | Read/Write. Path of root in hierarchy. Value displayed in status bar of schematic | 
| 'Reference' | Read/Write. Full component reference of block representing schematic. | 
| 'Readonly' | Read-only. Readonly status of schematic. Return value may be 'TRUE' or 'FALSE' | 
| 'UserStatus' | Read/Write. Contents of user status box at the bottom of the schematic. This is currently the 6th box from the left. | 
| 'UserVersion' | Read-only. Current version number of schematic. This is updated each time the schematic is saved | 
| 'ID' | Read-only. Returns ID of schematic (same value returned by OpenSchematic ) | 
| 'Magnification' | Read-only. Current view magnification | 
| 'Modified' | Modified status 'TRUE' or 'FALSE' | 
Path of schematic to process. This must be a schematic that is currently displayed; the function can not operate on a closed schematic.If not specified, the currently selected schematic will be processed.
Schematic handle.
Return type: string
Returns the value of the property
| ▲Function Summary▲ | ||
| ◄ ReadRegSetting | ReadSIMPLISF11Data ▶ | |