Returns value of schematic window property value.
Number | Type | Compulsory | Default | Description |
1 | string | Yes | Property name | |
2 | string | No | Currently displayed | Schematic path |
3 | number | No | Schematic handle |
'Path' | Read-only. File system path name of schematic |
'RootPath' | Read/Write. Path of root in hierarchy. Value displayed in status bar of schematic |
'Reference' | Read/Write. Full component reference of block representing schematic. |
'Readonly' | Read-only. Readonly status of schematic. Return value may be 'TRUE' or 'FALSE' |
'UserStatus' | Read/Write. Contents of user status box at the bottom of the schematic. This is currently the 6th box from the left. |
'UserVersion' | Read-only. Current version number of schematic. This is updated each time the schematic is saved |
'ID' | Read-only. Returns ID of schematic (same value returned by OpenSchematic ) |
'Magnification' | Read-only. Current view magnification |
'Modified' | Modified status 'TRUE' or 'FALSE' |
Path of schematic to process. This must be a schematic that is currently displayed; the function can not operate on a closed schematic.If not specified, the currently selected schematic will be processed.
Schematic handle.
Return type: string
Returns the value of the property
▲Function Summary▲ | ||
◄ ReadRegSetting | ReadSIMPLISF11Data ▶ |