After you configure the DVM control symbol, the schematic is ready to be run with one of
the built-in testplans. On the LTC 3406B circuit, each test in a testplan will typically
take approximately 6 seconds.
To run the built-in Sync Buck testplan, follow these steps:
- From the menu, select as shown below.
Result: The Choose Tests from syncbuck_1in_1out.testplan
test selection dialog opens.
- To select the six tests to run for this tutorial, check only the two items highlighted
in bold below:
- Ac Analysis > Bode Plot >
Vin Nominal (checking Vin Nominal selects all three tests under it)
- Steady-State > Steady-Stat >
Vin Nominal (checking Vin Nominal selects all three tests under it)
- Click Ok to run the six tests from the built-in sync buck testplan.
Result: DVM starts the test suite running the six selected
tests. For each test, DVM does the following:
- Selects symbols on the schematic, changes the property values, and sets the
analysis parameters.
- Opens the waveform viewer briefly to capture the waveform data from that
viewer.
After all six tests execute, the formatted overview report opens in your web
browser.
- If the test report fails to open, check the command shell window for text noting the
progress of the tests and any errors that may have occurred.